Xgiga's 155M/1.25G/2.5G/4G SFP include SR LR ER ZR,CWDM/DWDM,BIDI series,complaint withMSA,SFF-8472,with the feature of low power consumption,commerical or industrial operation temperature and high reliability,suitable for DC,Metro and Transmission networks.
Package | Part Number | Data Rate | Reach (km) |
Wavelength (nm) |
TX output (dBm) |
RX Sensitivity (dBm) |
Power Consumption | Interface | Temp | DataSheet |
---|---|---|---|---|---|---|---|---|---|---|
SFP | SF8542-02D | 4G | 0.3 | 850 | -9 ~-2.5 | -16 | LC | C/E/I | / | |
SFP | SF1342-05D | 4G | 5 | 1310 | -6 ~-1 | -18 | LC | C/E/I | / | |
SFP | SF1342-10D | 4G | 10 | 1310 | -6 ~-1 | -18 | LC | C/E/I | / | |
SFP | SF1342-40D | 4G | 40 | 1310 | -1 ~4 | -18 | LC | C/E/I | / | |
SFP | SF1542-40D | 4G | 40 | 1550 | -1 ~4 | -18 | LC | C/E/I | / | |
SFP | SF8524-02D | 2.5G | 0.5 | 850 | -10 ~-3 | -18 | LC | C/E/I | / | |
SFP | SF1324-02D | 2.5G | 2 | 1310 | -9 ~-3 | -18 | LC | C/E/I | / | |
SFP | SF1324-20D | 2.5G | 20 | 1310 | -5 ~0 | -19 | LC | C/E/I | / | |
SFP | SF1524-20D | 2.5G | 20 | 1550 | -5 ~0 | -19 | LC | C/E/I | / | |
SFP | SF1324-40D | 2.5G | 40 | 1310 | -2 ~3 | -19 | LC | C/E/I | / | |
SFP | SF1524-40D | 2.5G | 40 | 1550 | -2 ~3 | -19 | LC | C/E/I | / | |
SFP | SF1524-80D | 2.5G | 80 | 1550 | 0 ~5 | -28 | LC | C/E/I | / | |
SFP | SF1524-A0D | 2.5G | 100 | 1550 | 0 ~5 | -30 | LC | C/E/I | / | |
SFP | SF1524-C0D | 2.5G | 120 | 1550 | 1 ~6 | -30 | LC | C/E/I | / | |
SFP | SF8512-02D | 1.25G | 0.5 | 850 | -9 ~-3 | -17 | LC | C/E/I | / | |
SFP | SF1312-02D-M | 1.25G | 2 | 1310 | -9 ~-3 | -17 | LC | C/E/I | / | |
SFP | SF1312-10D | 1.25G | 10 | 1310 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP | SF1512-10 | 1.25G | 10 | 1550 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP | SF1312-15 | 1.25G | 15 | 1310 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP | SF1312-20D | 1.25G | 20 | 1310 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP | SF1312-40D | 1.25G | 40 | 1310 | -5 ~0 | -24 | LC | C/E/I | / | |
SFP | SF1512-40D | 1.25G | 40 | 1550 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP | SF1512-60 | 1.25G | 60 | 1550 | -5 ~0 | -26 | LC | C/E/I | / | |
SFP | SF1512-80D | 1.25G | 80 | 1550 | -5 ~0 | -26 | LC | C/E/I | / | |
SFP | SF1512-A0D | 1.25G | 100 | 1550 | -5 ~0 | -28 | LC | C/E/I | / | |
SFP | SF1512-C0D | 1.25G | 120 | 1550 | -5 ~0 | -31 | LC | C/E/I | / | |
SFP | SF1512-F0D | 1.25G | 160 | 1550 | -1 ~6 | -33 | LC | C/E/I | / | |
SFP | SF8503-02D | 155M | 0.5 | 850 | -9 ~-3 | -24 | LC | C/E/I | / | |
SFP | SF1303-02D | 155M | 2 | 1310 | -15~-8 | -24 | LC | C/E/I | / | |
SFP | SF1303-10D | 155M | 10 | 1310 | -15~-7 | -29 | LC | C/E/I | / | |
SFP | SF1303-20D | 155M | 20 | 1310 | -15~-7 | -29 | LC | C/E/I | / | |
SFP | SF1303-40D | 155M | 40 | 1310 | -7~-2 | -32 | LC | C/E/I | / | |
SFP | SF1503-40D | 155M | 40 | 1550 | -7~-2 | -32 | LC | C/E/I | / | |
SFP | SF1503-80D | 155M | 80 | 1550 | -5~0 | -33 | LC | C/E/I | / | |
SFP | SF1503-C0D | 155M | 120 | 1550 | -2~3 | -34 | LC | C/E/I | / | |
SFP CWDM | SF-CXX42-20D | 4G | 20 | CWDM | -1 ~4 | -17 | LC | C/I | / | |
SFP CWDM | SF-CXX42-40D | 4G | 40 | CWDM | -1 ~4 | -18 | LC | C/I | / | |
SFP CWDM | SF-CXX24-40D | 2.5G | 40 | CWDM | -2 ~3 | -19 | LC | C/I | / | |
SFP CWDM | SF-CXX24-80D | 2.5G | 80 | CWDM | 0 ~5 | -28 | LC | C/I | / | |
SFP CWDM | SF-CXX24-C0D | 2.5G | 120 | CWDM | 1 ~6 | -30 | LC | C/I | / | |
SFP CWDM | SF-CXX12-20D | 1.25G | 20 | CWDM | -9 ~-3 | -20 | LC | C/I | / | |
SFP CWDM | SF-CXX12-40D | 1.25G | 40 | CWDM | -5 ~0 | -24 | LC | C/I | / | |
SFP CWDM | SF-CXX12-80D | 1.25G | 80 | CWDM | 0~5 | -26 | LC | C/I | / | |
SFP CWDM | SF-CXX12-A0D | 1.25G | 100 | CWDM | 0~5 | -28 | LC | C/I | / | |
SFP CWDM | SF-CXX12-C0D | 1.25G | 120 | CWDM | 0~5 | -31 | LC | C/I | / | |
SFP CWDM | SF-CXX12-F0D | 1.25G | 160 | CWDM | 1~6 | -33 | LC | C/I | / | |
SFP CWDM | SF-CXX03-40D | 155M | 40 | CWDM | -7~-2 | -32 | LC | C/I | / | |
SFP CWDM | SF-CXX03-80D | 155M | 80 | CWDM | -5~0 | -33 | LC | C/I | / | |
SFP CWDM | SF-CXX03-C0D | 155M | 120 | CWDM | -2~3 | -34 | LC | C/I | / | |
SFP CWDM | SF-CXX03-F0D | 155M | 160 | CWDM | 0~5 | -35 | LC | C/I | / | |
SFP DWDM | SF-DXX42-40D | 4G | 40 | DWDM(100G HZ) | -1 ~4 | -18 | LC | C | / | |
SFP DWDM | SF-DXX42-80D | 4G | 80 | DWDM(100G HZ) | 0 ~5 | -26 | LC | C | / | |
SFP DWDM | SF-DH(C)XX24-40D | 2.5G | 40 | DWDM(50G HZ) | -2 ~3 | -19 | LC | C | / | |
SFP DWDM | SF-DXX24-40D | 2.5G | 40 | DWDM(100G HZ) | -2 ~3 | -19 | LC | C | / | |
SFP DWDM | SF-DH(C)XX24-80D | 2.5G | 80 | DWDM(50G HZ) | 0 ~4 | -28 | LC | C | / | |
SFP DWDM | SF-DXX24-80D | 2.5G | 80 | DWDM(100G HZ) | 0 ~4 | -28 | LC | C | / | |
SFP DWDM | SF-DH(C)XX24-C0D | 2.5G | 120 | DWDM(50G HZ) | 0 ~5 | -30 | LC | C | / | |
SFP DWDM | SF-DXX24-C0D | 2.5G | 120 | DWDM(100G HZ) | 0 ~5 | -30 | LC | C | / | |
SFP DWDM | SF-DH(C)XX12-40D | 1.25G | 40 | DWDM(50G HZ) | -2~3 | -24 | LC | C | / | |
SFP DWDM | SF-DXX12-40D | 1.25G | 40 | DWDM(100G HZ) | -2~3 | -24 | LC | C | / | |
SFP DWDM | SF-DH(C)XX12-80D | 1.25G | 80 | DWDM(50G HZ) | 0~4 | -26 | LC | C | / | |
SFP DWDM | SF-DXX12-80D | 1.25G | 80 | DWDM(100G HZ) | 0~4 | -26 | LC | C | / | |
SFP DWDM | SF-DH(C)XX12-C0D | 1.25G | 120 | DWDM(50G HZ) | 0~5 | -30 | LC | C | / | |
SFP DWDM | SF-DXX12-C0D | 155M | 120 | DWDM(100G HZ) | 0~5 | -30 | LC | C | / | |
SFP DWDM | SF-DXX03-80D | 155M | 80 | DWDM | 0~4 | -33 | LC | C | / | |
SFP DWDM | SF-DXX03-C0D | 155M | 120 | DWDM | 0~4 | -33 | LC | C | / | |
SFP BIDI | SFL35(53)42-05D | 4G | 5 | 1310/1550 | -6 ~-1 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)42-10D | 4G | 10 | 1310/1550 | -6 ~-1 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)42-20D | 4G | 20 | 1310/1550 | -1 ~4 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)42-40D | 4G | 40 | 1310/1550 | -1 ~4 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL3324-02D | 2.5G | 2 | 1310 | -9 ~-3 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)24-02D | 2.5G | 2 | 1310/1550 | -9 ~-3 | -18 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)24-10 | 2.5G | 10 | 1310/1490 | -5 ~0 | -19 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)24-20D | 2.5G | 20 | 1310/1550 | -5 ~0 | -19 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)24-40D | 2.5G | 40 | 1310/1550 | -2 ~3 | -19 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)24-40D | 2.5G | 40 | 1490/1550 | -2 ~3 | -19 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)24-80D | 2.5G | 80 | 1490/1550 | 0 ~5 | -26 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)12-03D | 1.25G | 3 | 1310/1490 | -11 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)12-03D | 1.25G | 3 | 1310/1550 | -11 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)12-10D | 1.25G | 10 | 1310/1550 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)12-20D | 1.25G | 20 | 1310/1490 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)12-20D | 1.25G | 20 | 1310/1550 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)12-20D | 1.25G | 20 | 1490/1550 | -9 ~-3 | -20 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)12-40D | 1.25G | 40 | 1310/1490 | -5 ~0 | -24 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)12-40D | 1.25G | 40 | 1310/1550 | -5 ~0 | -24 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)12-40D | 1.25G | 40 | 1490/1550 | -5 ~0 | -24 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)12-80D | 1.25G | 80 | 1310/1490 | 0~5 | -26 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)12-80D | 1.25G | 80 | 1310/1550 | 0~5 | -26 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)12-80D | 1.25G | 80 | 1490/1550 | 0~5 | -26 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)12-C0D | 1.25G | 120 | 1490/1550 | 0~5 | -31 | LC | C/E/I | / | |
SFP BIDI | SWL(4755/4957/5159/5361/ 5547/5749/5951/6153)12-C0D | 1.25G | 120 | CWDM | 0~5 | -31 | LC | C/I | / | |
SFP BIDI | SFL45(54)12-F0D/XGSF-BL45(54)12-F0D | 1.25G | 160 | 1490/1550 | 1~6 | -33 | LC | C/E/I | / | |
SFP BIDI | SFL34(43)03-20D | 155M | 20 | 1310/1490 | -15~-7 | -28 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)03-20D | 155M | 20 | 1310/1550 | -15~-7 | -28 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)03-40D | 155M | 40 | 1310/1550 | -7~-2 | -32 | LC | C/E/I | / | |
SFP BIDI | SFL35(53)03-80D | 155M | 80 | 1310/1550 | -5~0 | -32 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)03-80D | 155M | 80 | 1490/1550 | -5~0 | -33 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)03-C0D | 155M | 120 | 1490/1550 | -2~3 | -34 | LC | C/E/I | / | |
SFP BIDI | SFL45(54)03-F0D | 155M | 160 | 1490/1550 | 0~5 | -35 | LC | C/E/I | / |